All-In-One Weather Station
In Stock
Our solution is an all-in-one weather station…plus one. The all-new ATMOS 41 weather station is the first affordable all-in-one weather station that fulfills all your weather monitoring needs but doesn’t restrain you when you want to do more. ATMOS 41 weather data (e.g., humidity, temperature, or atmospheric pressure) are transmitted over a single wire. That means you don’t have to use all of the ports on your data logger just for weather measurements.
- Category : Meteorological Sensors
- Model Number : Atmos41
- Brand : METER
-
All-In-One Weather Station
Our solution is an all-in-one weather station…plus one. The all-new ATMOS 41 weather station is the first affordable all-in-one weather station that fulfills all your weather monitoring needs but doesn’t restrain you when you want to do more. ATMOS 41 weather data (e.g., humidity, temperature, or atmospheric pressure) are transmitted over a single wire. That means you don’t have to use all of the ports on your data logger just for weather measurements. -
Solar Radiation Range: 0 – 1750 W/m2, Resolution: 1 W/m2, Accuracy: ± 5% of measurement typical Precipitation Range: 0 – 400 mm/h, Resolution: 0.017 mm, Accuracy: ± 5% of measurement from 0 to 50 mm/h Relative Humidity (RH) Range: 0 – 100 % RH (0.00 – 1.00), Resolution: 0.1% RH, Accuracy: Varies with temperature and humidity, ±1.5% RH typical Air Temperature Range: –50 to 60 °C, Resolution: 0.10 °C, Accuracy: ±0.60 °C Humidity Sensor Temperature Range: –40 to 50 °C, Resolution: 0.10 °C, Accuracy: ± 1.0 °C Vapor Pressure Range: 0 – 47 kPa, Resolution: 0.01 kPa, Accuracy: Varies with temperature and humidity, ±0.2 kPa typical below 40 °C Barometric Pressure Range: 1 – 120 kPa, Resolution: 0.01 kPa, Accuracy: ±0.05 kPa at 25 °C, Equilibration: <10 ms, Long-term Drift: < 0.1 kPa/year, typical Horizontal Wind Speed Range: 0–30 m/s, Resolution: 0.01 m/s, Accuracy: The greater of 0.3 m/s or 3% of measurement Wind Gust Range: 0–30 m/s, Resolution: 0.01 m/s, Accuracy: The greater of 0.3 m/s or 3% of measurement Wind Direction Range: 0 – 359 °, Resolution: 1 °, Accuracy: ±5 ° Tilt Range: –90° to 90°, Resolution: 0.1°, Accuracy: ±1 ° Lightning Strike Count Range: 0 – 65,535 strikes, Resolution: 1 strike, Accuracy: Variable with distance, >25% detection at <10km typical Lightning Average Distance Range: 0 – 40 km, Resolution: 3 km, Accuracy: Variable Output SDI-12 communication Data Logger Compatibility METER ZL6 and EM60 data loggers or any data aquisition systems capable of switched 3.6- to 15.0-VDC excitation and SDI-12 communication Dimensions Diameter: 10.0 cm (3.9 in), Height: 28 cm (11.0 in), includes rain gauge filter Operating Temperature Range Minimum: –50 °C, Typical: NA, Maximum: 60 °C Cable Length 5 m (standard), 75 m (maximum custom cable length for additional cost) Cable Diameter 0.165 ±0.004 in (4.20 ±0.10 mm), with minimum jacket of 0.030 in (0.76 mm) Connector Types Stereo plug connector or stripped and tinned wires Stereo Plug Connector Diameter 3.5-mm Conductor Gauge 22-AWG / 24-AWG drain wire Supply Voltage (VCC to GND) Minimum: 3.6 VDC continuous, Typical: NA, Maximum: 15.0 VDC continuous Digital Input Voltage (Logic High) Minimum: 2.8 V, Typical: 3.0 V, Maximum: 5.5 V Digital Input Voltage (Logic Low) Minimum: -0.3 V, Typical: 0.0 V, Maximum: 0.8 V Digital Output Voltage (Logic High) Minimum: NA, Typical: 3.6 V, Maximum: NA Power Line Slew Rate Minimum: 1.0 V/ms Current Drain (During Measurement) Minimum: 0.2 mA, Typical: 8.0 mA, Maximum: 33.0 mA Current Drain (While Asleep) Minimum: 0.2 mA, Typical: 0.3 mA, Maximum: 0.4 mA Power Up Time (SDI Ready) — other commands Minimum: NA, Typical: 800 ms, Maximum: NA Power Up Time (SDI Ready) — aRx! commands Minimum: NA, Typical: 10 s, Maximum: NA Measurement Duration Minimum: NA, Typical: 110 ms, Maximum: 3000 ms -
Measures 12 weather variables including: air temperature, relative humidity, vapor pressure, barometric pressure, wind speed, gust and direction, solar radiation, precipitation, lightning strike counter and distanceEasy installationNo moving partsAll weather station data transmitted over a single wireDigital SDI-12 communicationConnect to ZL6 for data capture and managementDesigned for continuous deployment in harsh climatesNo louvered radiation shield to attract bugsAccurate at low wind speeds because no moving parts will cause friction or failDetects fine-scale wind speed variations with 0.01 m/s resolutionIntegrated weather station accelerometer detects if sensor is off-levelIntegrated spring acts as a rain gauge filter to keep out large particles but still allow enough water flowOptional bird deterrent fits perfectly on the weather station funnel
-
Solar Radiation Range: 0 – 1750 W/m2, Resolution: 1 W/m2, Accuracy: ± 5% of measurement typical Precipitation Range: 0 – 400 mm/h, Resolution: 0.017 mm, Accuracy: ± 5% of measurement from 0 to 50 mm/h Air Temperature Range: –50 to 60 °C, Resolution: 0.10 °C, Accuracy: ±0.60 °C Humidity Sensor Temperature Range: –40 to 50 °C, Resolution: 0.10 °C, Accuracy: ± 1.0 °C Vapor Pressure Range: 0 – 47 kPa, Resolution: 0.01 kPa, Accuracy: Varies with temperature and humidity, ±0.2 kPa typical below 40 °C Wind Gust Range: 0–30 m/s, Resolution: 0.01 m/s, Accuracy: The greater of 0.3 m/s or 3% of measurement Dimensions Diameter: 10.0 cm (3.9 in) Height: 28 cm (11.0 in), includes rain gauge filter